Dec 12, 2017 10:20:00 AM | 4 Min Read

Catastrophic Slurry Pump Cavitation — and How to Avoid It

Posted By
GIW Industries
Share

cavitation-new.jpg

GIW-KSB_Logo_RGB_stack-small.jpgAre you struggling with your centrifugal slurry pump? Maybe you’re dealing with serious pump damage, ranging from pump housing failure to impeller destruction. Perhaps you’re baffled by excess energy usage. Or, possibly most obvious of all, you could be hearing distinct popping noises while your pumps are operating.

If any of these sound familiar, you likely have cavitation to blame.

What is cavitation?

From a technical standpoint, cavitation occurs when the absolute pressure at the eye of the impeller reaches the vapor pressure. At this pressure, bubbles or “cavities” form in the liquid. As the bubbles move from the low-pressure area near the impeller toward the high-pressure area surrounding the pump discharge, they implode. 

These little implosions of collapsing bubbles cause loud popping noises, which operators can hear externally while their pumps are operating. Internally, this repeated popping creates shockwaves that can result in considerable physical damage. Over time, cavitation can destroy impellers and pump housing, result in seal and bearing failure, impact flow and pressure rates, and consume significantly more power.

Does your pump sound like this?
If it makes noises similar to popcorn popping, cavitation is likely to blame.

Depending on your application and setup, you could be experiencing suction cavitation or discharge cavitation. In either case, the end result can be very damaging — and very costly — to repair or replace.

How can I avoid — or fix — cavitation?

How Is Your Pump Holding Up?

Did you know pump vibration levels are an excellent diagnostic tool? Click here to view the GIW® Minerals chart of Pump Vibration Levels to see how your pump is holding up.

Naturally, the best way to fix a cavitating pump is to avoid cavitation altogether.

As far as general maintenance is concerned, it’s important to ensure your pipe and filters are free of blockages and that your pump is operating at its most efficient point on its pump curve. However, the most effective form of prevention is to select the right pump from the start. Find a centrifugal pump that operates far below the required critical suction pressure or net positive suction head (NPSH). It’s also important that your system’s flow in and out of the pump doesn’t exceed the pump’s capabilities.

By selecting a pump that’s an ideal fit for your pressure, flow, and overall application, cavitation should never be a concern. If you fear that cavitation is affecting your operations, it’s a good idea to get in touch with an expert who can help you diagnose precisely why. With the right pump — and the right partner — you can avoid this costly and catastrophic problem! 

The GIW Tech Services slurry pump experts can ensure you have the right pump for the job so cavitation doesn’t harm your system — or your bottom line. Contact us today to see what our highly experienced crew can do for you.

View all Blogs    Topics: GIW, Oil Sands

Related Posts

Mining, GIW, Oil Sands

Cavitation and NPSH

What is Cavitation?

Cavitation occurs when the absolute pressure at the eye of the impeller falls...

Read More
Mining, GIW

What is Vane Pass?

Pumps experience a wide variety of pressures and loads during operation, and it is important for...

Read More
Mining, GIW, Oil Sands

Meet the Professors — Interview with Václav Matoušek

Václav Matoušek is a respected professor who has been researching the topic of slurry transport...

Read More